THE WORLD OF AVIONICS COMMUNICATION IN YOUR HAND
MIL-STD-1553 STANAG 3838 ARINC-429
RS 232-422

PC104 Universal Avionics Design Interface
Features
MIL-STD-1553 Dual
Redundant Channels
ARINC 429, 575, 562, 572, 582..
ARINC 453, 708
RS 232, 422

Mil-Std-1553 Configurations

1553-Test and Simulation Features
§ On-board Built-In-Test
§ Transformer & direct coupling
§ BC & RT error injection/detection
§ Support F-16, F-18, B-52, and A-10. 1553 Notice I & II
§ BC, RT,BM, BCBM, BCRT & RTBM
§ Commercial and Industrial Grade

1553-Bus Controller - BC
§ BC->RT, RT->BC, RT->RT
§ Mode Codes, Broadcast
§ Single-shot or loop messaging mode
§ Programmable inter-message time delays
§ Response Gap measurement
§ Major/Minor frames
§ Software Programmable
§ Time-out response time
§ Enable/Disable Interrupt Conditions
§ Broadcast Enable/Disable (Notice I)
§ Status error Bit
§ Aperiodic messaging methods
§ Built-in Transmit/Receive Test

1553-Remote Terminal - RT
§ Up to 60 Store message buffers
§ Programmable response time Class A/B
§ Sub-Address programmable filter.
§ Long Loop Test Enable/Disable
§ 32-bit time-tagging

RS 232 & ARINC 429 575 562 572 582...

Test and Simulation Features
§ On-board Built-In-Test
§ Adv. interrupts and triggers
§ Support ARINC 2 & 6 wires protocol.
Transmit Mode
§ Software Programmable -:
§ Baud Rate – up to 1 Mbit
§ Parity Odd/Even/NO Parity
§ Loop Messaging Mode
§ Single-shot messaging mode
§ Programmable inter-message time delays
§ Independent transmit & receive channels
Receive Mode
§ Software Programmable Interrupt
§ Single message
§ Half buffer message
§ Full Buffers messages
§ Multiple store messages buffer
BMC's PC104-UADI provides new levels of performance and flexibility for multiple avionics communications system. Available in commercial and ruggedized versions, includes an API (Application Programming Interface) software library that reduces application development time. Standard 1553 features 32-bit message time-tagging, triggers, extensive BC & RT link-list structures, error injection and detection, automatic/manual RT Status Bit, Mode Code responses, advanced BC functionality, on-board Built-in-Test Bus, transformer & direct coupling, hardwired RT address. With the highest speed encoder/decoder in the industry Available in a range of configurations to match your needs, the intelligent PC104 - UADI provide complete, integrated databus functionality for ARINC 429 and related avionics protocols. The PC104 UADI supports maximum data throughput on all channels while providing on-board message scheduling, label filtering, multiple buffering options, time-tagging,. Standard features 32-bit message timetagging with Bus Monitor mode, triggers and extensive structures. On-board Built-in-Test with the highest speed encoder/decoder in the industry.

Multi-function Interfaces
PC104-UADI multi-function interfaces are easily software configured to operate with simultaneous 1553 Bus Controller, Remote Terminals and Bus Monitor functionality. the RS 232 and ARINC section supports maximum data throughput on all channels simultaneously, operates with independent receivers (2) and transmitters (2).

Multi-function 1553
The PC104-UADI interfaces have all the features and functionality of the multifunction versions, but with only one operational mode enabled at a time. Each interface can emulate either a Bus Controller (BC), Remote Terminal (RT) or Bus Monitor (BM) and concurrent modes BCRT, BCBM and RTBM.

Multi-function ARINC and RS232
The PC104-UADI are easily software programmable to supports maximum data throughput on all channels simultaneously, operates with independent receivers and transmitters.

BAUD RATE
The PC104-UADI has all the features and functionality to operate with any ARINC or RS232\422 transmit/receive rate ranging from 100 Hz to 1 Mega bit.

Software
The PC104-UADI API is provided in source code in C, Linux & Windows drivers, along with libraries to interface with the different protocols.
Physical
• 4" x 3.8”

CPU
• Low Power 16 bit RISC processor

Environmental
• Operating temperature range: 0°C to +70°C
• Available Extended Temperature -40°C to +85°C

Humidity
• Up to 95%

Software Support
• Source code API library provided

1553 Connections
• Direct or transformer coupling
• Input and output triggers

1553 Operational Modes
• BC, BM, single RT, concurrent BCRT, BCBM & RTBM

Single Power (1553- 50% duty cycle)
•  Stand-by Current less than 20 mA

Warranty: programs up to 3
years hardware
warranty

Product Description –ARINC & RS 232

Transmission Mode
• “One shot” mode for simplified BC operation (Normal mode)
“Loop” mode for simplified repeatable BC message operation
• Programmable transmit buffer size
Modify messages, data or setup while card is running
• Selectable interrupt generation

Receive Mode
• 2 independent Receivers.
• Programmable message content
Programmable receive buffer size
• Programmable labels selection

Bus Monitor
• Extensive filtering options
• 32-bit, resolution time tagging

Bus Controller
• Programmable control of:
          - Major and minor frame content and timing
          - Inter-message gap times (cycle mode)
          - Response time-out and late response
• Modify messages, data or setup while card is running
• Insert aperiodic messages into a running BC list
• “One shot” mode for simplified BC operation (Normal mode)
• ”Loop” mode for simplified repeatable BC message operation
• Multiple sequencing messages based on real-time schedule
• Selectable interrupt generation
          - Full range of system conditions
          - External trigger
• Full error detection
          - Response Gap (Late response)
          - Number of words
          - Time-Out
          - No response
          - Data/Command Parity error
          - Manchester Code Error
          - Long Loop Test
Extensive programmable error injection
Multiple Store buffers with 32 bit timetag

Remote Terminal
Programmable error injection
Programmable message content (linked message buffers)
Programmable Sub-Address selection
Multiple Store buffers with 32 bit timetag

Bus Monitor
Word status - Message status
RT response time
Interrupts can be selected by RT
Extensive filtering and triggering options
                 - By individual RT/subaddress
                 - Transmit, receive or broadcast mode codes
                 - Internal or external triggering
                 - Trigger output on user specified data
Up to 60 store buffers with 32 bit timetag
67 Bond Street  Westbury, NY 11590
Tel 516-997-2118 • Fax 516-997-2129 • www.bmccorp.com