THE WORLD OF AVIONICS COMMUNICATION IN YOUR HAND
PC104 MIL-STD-1553 STANAG 3838
Arinc-708, ARINC 453 & RS 232
MIL-STD-1553 PC104 Interface CRAM-1553 A/B
Features
MIL-STD-1553 Dual
Redundant Channels
Test and Simulation Features
On-board Built-In-Test
Transformer & direct coupling
BC & RT error injection/detection
Adv. interrupts and triggers
4K of Dual Port Memory
Support F-16, F-18, B-52, and A-10. 1553 Notice I & II
Commercial and Industrial Grade
Bus Controller - BC
BC->RT, RT->BC, RT->RT
Mode Codes, Broadcast
Five different transmission modes: Single-shot, repeat, loop , cycle and multiple messaging mode
Programmable inter-message time delays
Response Gap measurement
Major/Minor frames
Software Programmable
Time-out response time
Enable/Disable Interrupt Conditions
Broadcast Enable/Disable (Notice I)
Status error Bit
Aperiodic messaging methods
Built-in Transmit/Receive Test
Remote Terminal - RT
Up to 100 RT message buffers
Software Programmable Interrupt Conditions
Single, Half or Full number of message Buffers
Programmable response time Class A/B
Sub-Address software programmable filter.
Long Loop Test Enable/Disable
Bus Monitor - BM
Error detection
Multiple monitoring methods
32-bit time-tagging
Up to 100 messages buffer
BMC's Compact PC104-CRAM-MRT-1553 provides new levels of performance and flexibility for MILSTD1553A/B Notice II for PC104 form factors. Available in commercial and rugged versions, the
PC104-CRAM-1553
includes an API (Application
Programming Interface) software that reduces application development time.
Standard features include 4 Kbyte of RAM, 32-bit message time-tagging, triggers, extensive BC & RT link-list structures, error injection/detection, automatic/manual RT Status Bit, Mode Code responses, advanced BC functionality, on-board Built-in-Test Bus, transformer & direct coupling, hardwired RT address. With the highest speed encoder/decoder in the industry, the PC104-CRAM-1553 Bus Monitor provides unparalleled error detection and monitoring of fully loaded buses.
Multi-function Interfaces
cPC104-CRAM-MRT-1553 multi-function interfaces are easily software configured to operate with simultaneous Bus Controller, Remote Terminals and Bus Monitor functionality.
Single-function Interfaces
Single-function PC104-CRAM- 1553 interfaces have all the features and functionality of the multi-function versions, but with only one operational mode enabled at a time. Each interface can emulate either a Bus Controller or Remote Terminals or Bus Monitor.
Software
The 1553 API is provided in source code, along with integrated support for Windows XP, 2000, Me, NT, 98, 95, Visual Basic and other operating systems.
Physical
3.4” x 4.0”
Environmental
Operating temperature range: 0°C to +70°C
Available Extended Temperature -40°C to +85°C
Humidity
Up to 95%
Software Support
API - Includes high-level API libraries for Windows XP, 2000, Me, NT, 98, 95, Visual Basic
Source code API library provided
On-board Shared RAM
4 Kbyte (per dual-redundant channel)
Connections
Direct or transformer coupling
Input and output triggers
Operational Modes
BC, BM, single RT, Concurrent Modes BC-RT, BC-BM, RT-BM
Single Power (50% duty cycle)
+5 VDC: 0.3 A
Warranty: programs up to 3 years hardware warranty
RS232 Description - 2T2R
Transmission Mode
“One shot” mode (Normal mode)
“Loop” mode Programmable transmit buffer size
Modify messages, data or setup while card is running
Selectable interrupt generation
Receive Mode
2 independent Receivers.
Programmable message content
Programmable receive buffer size
Programmable Interrupts condition
Bus Monitor
Programmable receive buffer size
Multiple message buffers
32-bit, resolution time tagging
1553- Bus Controller
Programmable control of:
- Major and minor frame content and timing
- Inter-message gap times (cycle mode)
- Response time-out and late response
Modify messages, data or setup while card is running
Insert aperiodic messages into a running BC list
“One shot” mode for simplified BC operation (Normal mode)
“Loop” mode for simplified repeatable BC message operation
Multiple sequencing messages based on
real-time schedule
Selectable interrupt generation
- Full range of system conditions
- All detected errors
Full error detection
- Response Gap (Late response)
- Number of words
- Word count error
- Time-Out
- No response
- Data/Command Parity error
- Manchester Code Error
Extensive programmable error injection (on a per word basis)
1553- Remote Terminal
Programmable error injection (on a per word basis)
Modify data, status words or setup while card is running
Programmable message content (linked message buffers)
Up to 100 message buffers
Programmable Interrupts conditions
Programmable Sub-Address selection
1553- Bus Monitor
Word status - Message status
RT response time
Interrupts can be selected by RT/SA/WC
Extensive filtering and triggering options
- By individual RT/subaddress
- Transmit, receive or broadcast mode codes
- Internal or external triggering
- Trigger output on user specified data
Real-time bus playback with RT edit mode
32-bit, 16 Mhz resolution time tagging
Host software synchronization to external timing sources
67 Bond Street Westbury, NY 11590
Tel 516-997-2118 • Fax 516-997-2129 • www.bmccorp.com
Specifications